Testosterone: Survey Deficiencies and CLIA Citations
Most Testosterone citations come from five places: quality control (42 CFR 493.1256), calibration verification (42 CFR 493.1255), proficiency testing or accuracy verification, method verification (42 CFR 493.1253) and test reporting, including critical values (42 CFR 493.1291). Keep the records for each area current and you remove most of the risk.
Where Testosterone citations come from
Survey findings about Testosterone almost always trace to a short list of 42 CFR 493 standards. This table shows each one and the records a surveyor will usually ask to see.
| Area | Regulation | Records surveyors ask for |
|---|---|---|
| QC | 42 CFR 493.1256 | Daily Testosterone QC records, Levey-Jennings charts, corrective action log, control lot ranges |
| Calibration verification | 42 CFR 493.1255 | Six-month Testosterone calibration verification and reportable range data with director review |
| Proficiency testing | 42 CFR 493.801, Subpart H | Testosterone PT enrollment, attestation statements, graded reports, investigation of every miss |
| Method verification | 42 CFR 493.1253 | Testosterone verification study: accuracy, precision, reportable range, reference interval check, director sign-off |
| Test report and critical values | 42 CFR 493.1291 | Critical value list, call log with read-back, report format showing Testosterone reference intervals |
| Personnel | Subpart M | Training and competency records for everyone who runs Testosterone |
PT status for Testosterone
Testosterone is a regulated analyte (endocrinology, 42 CFR 493.933). CLIA PT acceptance limit: target value ±30% or ±20 ng/dL (greater).
Specimen problems that turn into Testosterone findings
Preanalytical errors become citations when the lab has no written rule for them, or does not follow its own rule.
- Testosterone has diurnal variation; morning collection is common practice, so record the time.
- Immunoassays may be less accurate at low concentrations (women, children); mass spectrometry may be used.
- Clinics running testosterone in house need the correct CLIA certificate for nonwaived testing.
If Testosterone was cited on your survey
- Identify the exact standard cited and the records the surveyor reviewed.
- Look back at patient results that could have been affected and decide whether corrected reports are needed.
- Fix the system, not just the instance, and assign monitoring.
- Write the plan of correction. See the CLIA plan of correction guide.
Related tests
- Estradiol
- PSA (Prostate-Specific Antigen), Total (full guide)
- LH (Luteinizing Hormone) (full guide)
- FSH (Follicle-Stimulating Hormone) (full guide)
Full guide: Testosterone testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.
Want a gap check before the next survey?
Sound Lab Consultants reviews laboratories phase by phase against CLIA requirements and helps fix D-tag deficiencies after a survey.
Related guides on soundlabconsult.com:
Frequently asked questions
What are the most common Testosterone survey deficiencies?
Missing or undocumented QC, missed calibration verification, PT or accuracy verification gaps, no method verification study, and undocumented critical value calls for Testosterone. These are general categories, not statistics.
Which regulation covers Testosterone quality control?
42 CFR 493.1256 sets the control procedure requirements.
Is Testosterone on the CLIA PT analyte list?
Testosterone is a regulated analyte (endocrinology, 42 CFR 493.933). CLIA PT acceptance limit: target value ±30% or ±20 ng/dL (greater).
Sources
- 42 CFR 493.933, Endocrinology
- 42 CFR 493.1256, Control procedures
- 42 CFR 493.1255, Calibration and calibration verification
- 42 CFR 493.1253, Establishment and verification of performance specifications
- 42 CFR 493.1291, Test report
- 42 CFR 493.1236, Evaluation of proficiency testing performance
- CMS CLIA Year 2024 Top 10 Standard- and Condition-Level Deficiencies
- CMS State Operations Manual, Appendix C (Laboratories)